Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Diagn Interv Imaging ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38368176

RESUMO

PURPOSE: The purpose of this study was to evaluate the capabilities of photon-counting (PC) CT combined with artificial intelligence-derived coronary computed tomography angiography (PC-CCTA) stenosis quantification and fractional flow reserve prediction (FFRai) for the assessment of coronary artery disease (CAD) in transcatheter aortic valve replacement (TAVR) work-up. MATERIALS AND METHODS: Consecutive patients with severe symptomatic aortic valve stenosis referred for pre-TAVR work-up between October 2021 and June 2023 were included in this retrospective tertiary single-center study. All patients underwent both PC-CCTA and ICA within three months for reference standard diagnosis. PC-CCTA stenosis quantification (at 50% level) and FFRai (at 0.8 level) were predicted using two deep learning models (CorEx, Spimed-AI). Diagnostic performance for global CAD evaluation (at least one significant stenosis ≥ 50% or FFRai ≤ 0.8) was assessed. RESULTS: A total of 260 patients (138 men, 122 women) with a mean age of 78.7 ± 8.1 (standard deviation) years (age range: 51-93 years) were evaluated. Significant CAD on ICA was present in 126/260 patients (48.5%). Per-patient sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 96.0% (95% confidence interval [CI]: 91.0-98.7), 68.7% (95% CI: 60.1-76.4), 74.3 % (95% CI: 69.1-78.8), 94.8% (95% CI: 88.5-97.8), and 81.9% (95% CI: 76.7-86.4) for PC-CCTA, and 96.8% (95% CI: 92.1-99.1), 87.3% (95% CI: 80.5-92.4), 87.8% (95% CI: 82.2-91.8), 96.7% (95% CI: 91.7-98.7), and 91.9% (95% CI: 87.9-94.9) for FFRai. Area under the curve of FFRai was 0.92 (95% CI: 0.88-0.95) compared to 0.82 for PC-CCTA (95% CI: 0.77-0.87) (P < 0.001). FFRai-guidance could have prevented the need for ICA in 121 out of 260 patients (46.5%) vs. 97 out of 260 (37.3%) using PC-CCTA alone (P < 0.001). CONCLUSION: Deep learning-based photon-counting FFRai evaluation improves the accuracy of PC-CCTA ≥ 50% stenosis detection, reduces the need for ICA, and may be incorporated into the clinical TAVR work-up for the assessment of CAD.

3.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
4.
Diagn Interv Imaging ; 2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37550171

RESUMO

PURPOSE: The purpose of this study was to assess the diagnostic capabilities of cardiac magnetic resonance (CMR) T2* mapping in detecting incidental hepatic and cardiac iron overload. MATERIALS AND METHODS: Patients with various clinical indications for CMR examination were consecutively included at a single center from January 2019 to April 2023. All patients underwent T2* mapping at 1.5 T in a single mid-ventricular short-axis as part of a comprehensive routine CMR protocol. T2* measurements were performed of the heart (using a region-of-interest in the interventricular septum) and the liver, categorized according to the severity of iron overload. The degree of cardiac iron overload was categorized as mild (15 ms < T2* < 20 ms), moderate (10 ms < T2* < 15 ms) and severe (T2* < 10 ms). The degree of hepatic iron overload was categorized as mild (4 ms < T2* < 8 ms), moderate (2 ms < T2* < 4 ms), severe (T2* < 2 ms). Image quality and inter-reader agreement were assessed using intraclass correlation coefficient (ICC). RESULTS: CMR examinations from 614 patients (374 men, 240 women) with a mean age of 50 ± 18 (standard deviation) years were fully evaluable. A total of 24/614 patients (3.9%) demonstrated incidental hepatic iron overload; of these, 22/614 patients (3.6%) had mild hepatic iron overload, and 2/614 patients (0.3%) had moderate hepatic iron overload. Seven out of 614 patients (1.1%) had incidental cardiac iron overload; of these, 5/614 patients (0.8%) had mild iron overload, 1/614 patients (0.2%) had moderate iron overload, and 1/614 patients (0.2%) had severe iron overload. Good to excellent inter-reader agreement was observed for the assessment of T2* values (ICC, 0.90 for heart [95% confidence interval: 0.88-0.91]; ICC, 0.91 for liver [95% confidence interval: 0.89-0.92]). CONCLUSION: Analysis of standard CMR T2* maps detects incidental cardiac and hepatic iron overload in 1.1% and 3.9% of patients, respectively, which may have implications for further patient management. Therefore, despite an overall low number of incidental abnormal findings, T2* imaging may be included in a standardized comprehensive CMR protocol.

5.
BMC Gastroenterol ; 23(1): 241, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460992

RESUMO

PURPOSE: To evaluate efficacy, safety, and outcomes of endovascular treatment of hepatic vein stenosis post major liver resection. METHODS: A retrospective data analysis was performed including all interventional treatments of hepatic vein stenosis post major liver resection since 2010. Post procedural course and clinical parameters including amount of ascites accumulation and relevant laboratory values were assessed during the follow-up period. Primary and primary assisted hepatic venous patency time were calculated. RESULTS: Twelve patients (median age 55.5, IQR 49.75 to 61.5 years) undergoing a total of 16 interventions were included. Interventions were primary stent placement (n = 3), primary balloon angioplasty (n = 8), three re-interventions and two aborted interventions (no significant pressure gradient). Technical success was 100% (16/16). Permanent reduction and / or complete resolution of ascites was achieved in 72% (8/11). Laboratory parameters related to liver function did not show significant improvement after intervention. Median follow-up period was 6 months (IQR: 1.5 to 18 months). The median primary patency time for patients with balloon angioplasty was 11 months (IQR: 1.375 to 22.25 months) and assisted patency time was 13.25 months (IQR: 4.5 to 22.25 months). The median primary patency time for patients with angioplasty and stent placement was 1 months (IQR: 1.0 to 1.5 months) and assisted patency time was 2.0 months (IQR: 1.5 to 2.5months). CONCLUSION: An endovascular approach for the treatment of hepatic venous stenosis post major liver resection is safe and efficient to reduce and / or resolve refractory ascites. However, liver function parameters seem not to be improved by the procedure. Stent placement can be a reasonable option in patients with significant residual stenotic disease post angioplasty.


Assuntos
Angioplastia com Balão , Síndrome de Budd-Chiari , Procedimentos Endovasculares , Transplante de Fígado , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ascite/etiologia , Ascite/terapia , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Resultado do Tratamento , Angioplastia com Balão/métodos , Stents
6.
Diagnostics (Basel) ; 13(9)2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37175026

RESUMO

(1) Background and Objectives: Dark-blood late gadolinium enhancement has been shown to be a reliable cardiac magnetic resonance (CMR) method for assessing viability and depicting myocardial scarring in ischemic cardiomyopathy. The aim of this study was to evaluate dark-blood LGE imaging compared with conventional bright-blood LGE for the detection of myocardial scarring in non-ischemic cardiomyopathies. (2) Materials and Methods: Patients with suspected non-ischemic cardiomyopathy were prospectively enrolled in this single-centre study from January 2020 to March 2023. All patients underwent 1.5 T CMR with both dark-blood and conventional bright-blood LGE imaging. Corresponding short-axis stacks of both techniques were analysed for the presence, distribution, pattern, and localisation of LGE, as well as the quantitative scar size (%). (3) Results: 343 patients (age 44 ± 17 years; 124 women) with suspected non-ischemic cardiomyopathy were examined. LGE was detected in 123 of 343 cases (36%) with excellent inter-reader agreement (κ 0.97-0.99) for both LGE techniques. Dark-blood LGE showed a sensitivity of 99% (CI 98-100), specificity of 99% (CI 98-100), and an accuracy of 99% (CI 99-100) for the detection of non-ischemic scarring. No significant difference in total scar size (%) was observed. Dark-blood imaging with mean 5.35 ± 4.32% enhanced volume of total myocardial volume, bright-blood with 5.24 ± 4.28%, p = 0.84. (4) Conclusions: Dark-blood LGE imaging is non-inferior to conventional bright-blood LGE imaging in detecting non-ischemic scarring. Therefore, dark-blood LGE imaging may become an equivalent method for the detection of both ischemic and non-ischemic scars.

7.
Diagnostics (Basel) ; 13(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37189555

RESUMO

BACKGROUND: To compare the diagnostic characteristics between arterial phase imaging versus portal venous phase imaging, applying polychromatic T3D images and low keV virtual monochromatic images using a 1st generation photon-counting CT detector, of CT in patients with hepatocellular carcinoma (HCC). METHODS: Consecutive patients with HCC, with a clinical indication for CT imaging, were prospectively enrolled. Virtual monoenergetic images (VMI) were reconstructed at 40 to 70 keV for the PCD-CT. Two independent, blinded radiologists counted all hepatic lesions and quantified their size. The lesion-to-background ratio was quantified for both phases. SNR and CNR were determined for T3D and low VMI images; non-parametric statistics were used. RESULTS: Among 49 oncologic patients (mean age 66.9 ± 11.2 years, eight females), HCC was detected in both arterial and portal venous scans. The signal-to-noise ratio, the CNR liver-to-muscle, the CNR tumor-to-liver, and CNR tumor-to-muscle were 6.58 ± 2.86, 1.40 ± 0.42, 1.13 ± 0.49, and 1.53 ± 0.76 in the arterial phase and 5.93 ± 2.97, 1.73 ± 0.38, 0.79 ± 0.30, and 1.36 ± 0.60 in the portal venous phase with PCD-CT, respectively. There was no significant difference in SNR between the arterial and portal venous phases, including between "T3D" and low keV images (p > 0.05). CNRtumor-to-liver differed significantly between arterial and portal venous contrast phases (p < 0.005) for both "T3D" and all reconstructed keV levels. CNRliver-to-muscle and CNRtumor-to-muscle did not differ in either the arterial or portal venous contrast phases. CNRtumor-to-liver increased in the arterial contrast phase with lower keV in addition to SD. In the portal venous contrast phase, CNRtumor-to-liver decreased with lower keV; whereas, CNRtumor-to-muscle increased with lower keV in both arterial and portal venous contrast phases. CTDI and DLP mean values for the arterial upper abdomen phase were 9.03 ± 3.59 and 275 ± 133, respectively. CTDI and DLP mean values for the abdominal portal venous phase were 8.75 ± 2.99 and 448 ± 157 with PCD-CT, respectively. No statistically significant differences were found concerning the inter-reader agreement for any of the (calculated) keV levels in either the arterial or portal-venous contrast phases. CONCLUSIONS: The arterial contrast phase imaging provides higher lesion-to-background ratios of HCC lesions using a PCD-CT; especially, at 40 keV. However, the difference was not subjectively perceived as significant.

8.
Aesthetic Plast Surg ; 47(6): 2242-2252, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37253846

RESUMO

BACKGROUND: Macromastia, micromastia and breast asymmetry have an impact on health and quality of life. However, there is scarce information addressing breast size and asymmetry frequency distribution in reference populations. OBJECTIVE: The current study aims to identify factors that influence breast size and symmetry and classifies abnormal breast sizes and breast asymmetries in an adult German population. METHODS: Breast base dimensions, breast volume, symmetry, and other breast anthropometric parameters of 400 German female patients were determined in a retrospective review of the MRI archives at our institution. Professional medical MRI-segmentation software was used for volume measurement. RESULTS: A total of 400 Patients were retrospectively enrolled. The patients had a mean age of 50 ± 12 years (min: 24; max: 82), mean BMI of 25.0 ± 5.0 (min: 14.7, max: 45.6), and a mean total breast volume of 976 ml (right: 973 ml, min: 64, max: 4777; left: 979 ml, min: 55, max: 4670). The strongest correlation of breast volume was observed with BMI (r = 0.834, p < 0.001), followed by breast base width (r = 0.799, p < 0.001). Smaller breasts have higher breast volume asymmetry ratios (r = - 0.124, p < 0.014). For a BMI between 18.5 and 24.9 kg/m2, micromastia is defined by breast volumes below 250 ml (5th percentile) and macromastia by volumes above 1250 ml (95th percentile). Abnormal breast volume asymmetry (< 5th and > 95th percentile) is equivalent to an absolute difference of approximately 25% relative to the smallest side (bidirectional asymmetry ratio 5th percentile - 19%; 95th percentile 26%). CONCLUSION: This study provides normative data of German women, as well as selected size-for-BMI percentiles and asymmetry ratio percentiles. The normative data may help to establish transparent and objective coverage criteria for health insurances. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Mama/anormalidades , Hipertrofia , Mamoplastia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Estudos de Coortes , Estudos Retrospectivos , Mamoplastia/métodos , Qualidade de Vida , Resultado do Tratamento , Estética
9.
Tomography ; 9(2): 706-716, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36961015

RESUMO

The purpose of this study was to evaluate whether changes in repeated lung ultrasound (LUS) or chest X-ray (CXR) of coronavirus disease 2019 (COVID-19) patients can predict the development of severe disease and the need for treatment in the intensive care unit (ICU). In this prospective monocentric study, COVID-19 patients received standardized LUS and CXR at day 1, 3 and 5. Scores for changes in LUS (LUS score) and CXR (RALE and M-RALE) were calculated and compared. Intra-class correlation was calculated for two readers of CXR and ROC analysis to evaluate the best discriminator for the need for ICU treatment. A total of 30 patients were analyzed, 26 patients with follow-up LUS and CXR. Increase in M-RALE between baseline and follow-up 1 was significantly higher in patients with need for ICU treatment in the further hospital stay (p = 0.008). Both RALE and M-RALE significantly correlated with LUS score (r = 0.5, p < 0.0001). ROC curves with need for ICU treatment as separator were not significantly different for changes in M-RALE (AUC: 0.87) and LUS score (AUC: 0.79), both being good discriminators. ICC was moderate for RALE (0.56) and substantial for M-RALE (0.74). The present study demonstrates that both follow-up LUS and CXR are powerful tools to track the evolution of COVID-19, and can be used equally as predictors for the need for ICU treatment.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico por imagem , Estudos Prospectivos , Sons Respiratórios , Raios X , Pulmão/diagnóstico por imagem
10.
Rofo ; 195(8): 691-698, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36863367

RESUMO

BACKGROUND: Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. KEY POINTS: · Photon-counting computed tomography (PCCT) has been implemented in the clinical routine. · Compared to energy-integrating detector CT, PCCT allows the reduction of electronic image noise. · PCCT provides increased spatial resolution and a higher contrast-to-noise ratio. · The novel detector technology allows the quantification of spectral information. CITATION FORMAT: · Stein T, Rau A, Russe MF et al. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. Fortschr Röntgenstr 2023; 195: 691 - 698.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
11.
Int J Cardiovasc Imaging ; 39(5): 1023-1030, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36781568

RESUMO

To evaluate Quiescent Interval Slice Selective (QISS) balanced steady-state free precession (bSSFP) and QISS fast low-angle shot (FLASH) sequences for non-contrast Magnetic Resonance Angiography (MRA) of iliac arteries regarding image quality and diagnostic confidence in order to establish these sequences in daily clinical practice. A prospective study of healthy subjects (n = 10) was performed. All subjects underwent the QISS MRI protocol with bSSFP und FLASH sequences. Vessel contrast-to-background ratio (VCBR) were measured in pre-defined vessel segments. Image quality and diagnostic confidence was assessed using a Likert scale (five-point scale). Inter-reader agreement was determined using Cohen's kappa coefficient (κ). Ten healthy subjects (median age 29 years, IQR: 26.25 to 30 years) were included in this prospective study. Median MR examination time was 2:05 min (IQR 1:58 to 2:16) for QISS bSSFP and 4:11 min (IQR 3:57 to 4:32) for QISS FLASH. Both sequences revealed good VCBR in all examined vessel segments. VCBR (muscle tissue) were marginally higher for FLASH sequences (e.g., 0.82 vs. 0.78 in the right femoral artery, p = 0.035*), while bSSFP sequence showed significantly higher VCBR (fat tissue) in the majority of examined arterials vessels (e.g., 0.78 vs. 0.62 in right femoral artery, p = 0.001*). The image quality and diagnostic confidence of both sequences were rated as good to excellent. Moderate to good inter-reader agreement was found. QISS MRA using bSSFP and FLASH sequences are diagnostic for visualization of iliac arterial vasculature. The QISS bSSFP sequence might offer advantages due to the markedly shorter exam time and superior visualization of smaller vessels. The QISS FLASH sequence seems to be a robust alternative for non-contrast MRA since it is less sensitive to magnetic field inhomogeneities.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Adulto , Estudos Prospectivos , Valor Preditivo dos Testes , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Meios de Contraste
12.
Acad Radiol ; 30(5): 855-862, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35760710

RESUMO

RATIONAL AND OBJECTIVES: Comparison of radiation dose and image quality in routine abdominal and pelvic contrast-enhanced computed tomography (CECT) between a photon-counting detector CT (PCD-CT) and a dual energy dual source CT (DSCT). MATERIALS AND METHODS: 70 oncologic patients (mean age 66 ± 12 years, 29 females) were prospectively enrolled between November 2021 and February 2022. Abdominal CECT were clinically indicated and performed first on a 2nd-generation DSCT and at follow-up on a 1st-generation dual-source PCD-CT. The same contrast media (Imeron 350, Bracco imaging) and pump protocol was used for both scans. For both scanners, polychromatic images were reconstructed with 3mm slice thickness and comparable kernel (I30f[DSCT] and Br40f[PCD-CT]); for PCD-CT data from all counted events above the lowest energy threshold at 20 keV ("T3D") were used. Results were compared in terms of radiation dose metrics of CT dose index (CTDIvol), dose length product (DLP) and size-specific dose estimation (SSDE), objective and subjective measurements of image quality were scored by two emergency radiologists including lesion conspicuity. RESULTS: Median time interval between the scans was 4 months (IQR: 3-6). CNRvessel and SNRvessel of T3D reconstructions from PCD-CT were significantly higher than those of DSCT (all, p < 0.05). Qualitative image noise analysis from PCD-CT and DSCT yielded a mean of 4 each. Lesion conspicuity was rated significantly higher in PCD-CT (Q3 strength) compared to DSCT images. CTDI, DLP and SSDE mean values for PCD-CT and DSCT were 7.98 ± 2.56 mGy vs. 14.11 ± 2.92 mGy, 393.13 ± 153.55 mGy*cm vs. 693.61 ± 185.76 mGy*cm and 9.98 ± 2.41 vs. 14.63 ± 1.63, respectively, translating to a dose reduction of around 32% (SSDE). CONCLUSION: PCD-CT enables oncologic abdominal CT with a significantly reduced dose while keeping image quality similar to 2nd-generation DSCT.


Assuntos
Abdome , Redução da Medicação , Doses de Radiação , Tomografia por Raios X , Tomografia por Raios X/métodos , Abdome/diagnóstico por imagem , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Intensificação de Imagem Radiográfica
13.
Int J Comput Assist Radiol Surg ; 18(2): 339-351, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35962904

RESUMO

PURPOSE: To find out if the use of different virtual monoenergetic data sets enabled by DECT technology might have a negative impact on post-processing applications, specifically in case of the "unfolded ribs" algorithm. Metal or beam hardening artifacts are suspected to generate image artifacts and thus reduce diagnostic accuracy. This paper tries to find out how the generation of "unfolded rib" CT image reformates is influenced by different virtual monoenergetic CT images and looks for possible improvement of the post-processing tool. MATERIAL AND METHODS: Between March 2021 and April 2021, thin-slice dual-energy CT image data of the chest were used creating "unfolded rib" reformates. The same data sets were analyzed in three steps: first the gold standard with the original algorithm on mixed image data sets followed by the original algorithm on different keV levels (40-120 keV) and finally using a modified algorithm which in the first step used segmentation based on mixed image data sets, followed by segmentation based on different keV levels. Image quality (presence of artifacts), lesion and fracture detectability were assessed for all series. RESULTS: Both, the original and the modified algorithm resulted in more artifact-free image data sets compared to the gold standard. The modified algorithm resulted in significantly more artifact-free image data sets at the keV-edges (40-120 keV) compared the original algorithm. Especially "black artifacts" and pseudo-lesions, potentially inducing false positive findings, could be reduced in all keV level with the modified algorithm. Detection of focal sclerotic, lytic or mixed (k = 0.990-1.000) lesions was very good for all keV levels. The Fleiss-kappa test for detection of fresh and old rib fractures was ≥ 0.997. CONCLUSION: The use of different virtual monoenergetic keVs for the "unfolded rib" algorithm is generating different artifacts. Segmentation-based artifacts could be eliminated by the proposed new algorithm, showing the best results at 70-80 keV.


Assuntos
Parede Torácica , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Costelas/diagnóstico por imagem , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Estudos Retrospectivos
14.
Eur Radiol ; 33(4): 2945-2953, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36474057

RESUMO

OBJECTIVE: To evaluate the impact of the digital mammography imaging system on overall background enhancement on recombined contrast-enhanced spectral mammography (CESM) images, the overall background enhancement of two different mammography systems was compared. METHODS: In a retrospective single-center study, CESM images of n = 129 female patients who underwent CESM between 2016 and 2019 were analyzed independently by two radiologists. Two mammography machines of different manufacturers were compared qualitatively using a Likert-scale from 1 (minimal) to 4 (marked overall background enhancement) and quantitatively by placing a region of interest and measuring the intensity enhancement. Lesion conspicuity was analyzed using a Likert-scale from 1 (lesion not reliably distinguishable) to 5 (excellent lesion conspicuity). A multivariate regression was performed to test for potential biases on the quantitative results. RESULTS: Significant differences in qualitative background enhancement measurements between machines A and B were observed for both readers (p = 0.003 and p < 0.001). The quantitative evaluation showed significant differences in background enhancement with an average difference of 75.69 (99%-CI [74.37, 77.02]; p < 0.001). Lesion conspicuity was better for machine A for the first and second reader respectively (p = 0.009 and p < 0.001). The factor machine was the only influencing factor (p < 0.001). The factors contrast agent, breast density, age, and menstrual cycle could be excluded as potential biases. CONCLUSION: Mammography machines seem to significantly influence overall background enhancement qualitatively and quantitatively; thus, an impact on diagnostic accuracy appears possible. KEY POINTS: • Overall background enhancement on CESM differs between different vendors qualitatively and quantitatively. • Our retrospective single-center study showed consistent results of the qualitative and quantitative data analysis of overall background enhancement. • Lesion conspicuity is higher in cases of lower background enhancement on CESM.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Estudos Retrospectivos , Mamografia/métodos , Meios de Contraste/farmacologia , Densidade da Mama , Projetos de Pesquisa , Neoplasias da Mama/diagnóstico por imagem , Sensibilidade e Especificidade
15.
Eur Radiol ; 33(4): 2415-2425, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36350390

RESUMO

OBJECTIVE: Subjective and objective image quality comparison of bone microstructure and disease-related abnormalities in multiple myeloma patients using a 1st-generation dual-source photon-counting detector CT(DS-PCD-CT) and a 2nd-generation dual-source dual-energy (energy-integrating detector) CT (DS-EID-CT). METHODS: Fifty multiple myeloma patients (mean age 67.7 ± 10.9 years,16 females) were prospectively enrolled. Unenhanced whole-body CTs were clinically indicated and performed on DS-EID-CT and DS-PCD-CT (median time difference: 12 months). DS-PCD-CT was performed in Quantumplus UHR mode and DS-EID-CT was performed using dual-energy mode. DS-PCD-CT kernel was set at Br64 with Quantum iterative reconstruction strength Q1; for DS-EID-CT a comparable I70f kernel with SAFIRE iterative reconstruction strength 1 was used. Two independent radiologists assessed image quality subjectively using a 5-point Likert scale considering delineation and sharpness of trabecular bone and lytic bone lesions in the spine and pelvic bones. Additionally, ImageJ was used for quantification of bony septa inside the cancellous bone and through or the edges of osteolysis. RESULTS: Overall quality as well as detectability and sharpness in the delineation of lytic bone lesions were superior for DS-PCD-CT compared with DS-EID-CT (p < 0.0001). The inter-reader agreement for subjective image quality readings showed excellent consistency(α = 94.2-98.8). CTDI and DLP mean values for DS-PCD-CT and DS-EID-CT were 1107.4 ± 247.6 mGy*cm and 8.2 ± 1.8 mGy vs. 1344.3 ± 204.6 mGy*cm and 10.1 ± 1.9 mGy. The quantitative metric for bone microstructure in the femoral head showed significantly better visualization of trabeculae in DS-PCD-CT compared with DS-EID-CT (p < 0.0001). Quantitative analyses of edge sharpness of osteolysis showed significant steeper edges for DS-PCD-CT (p < 0.0001). CONCLUSION: DS-PCD-CT significantly improves spatial resolution of bony microstructure and lytic bone lesions compared to DS-EID-CT. KEY POINTS: • Application of photon-counting detector CT is superior to dual-source dual-energy integrating detector in clinical workup of multiple myeloma patients. • Compared to energy integrating detectors, photon-counting detectors significantly increase the spatial resolution of bone microstructure including disease-related lytic bone lesions in patients with multiple myeloma.


Assuntos
Mieloma Múltiplo , Osteólise , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Mieloma Múltiplo/diagnóstico por imagem , Osteólise/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Fótons
16.
Eur J Radiol ; 169: 111153, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38250749

RESUMO

PURPOSE: To compare image quality of contrast-enhanced abdominal-CT using 1st-generation Dual Source Photon-Counting Detector CT (DS-PCD-CT) versus 2nd-generation Dual-Source Energy Integrating-Detector CT (DS-EID-CT) in patients with BMI ≥ 25, applying two different contrast agent volumes, vendor proposed protocols and different virtual monoenergetic images (VMI). METHOD: 68 overweight (BMI ≥ 25 kgm2) patients (median age: 65 years; median BMI 33.3 kgm2) who underwent clinically indicated, portal-venous contrast-enhanced abdominal-CT on a commercially available 1st-generation DS-PCD-CT were prospectively included if they already have had a pre-exam on 2nd-generation DS-EID-CT using a standardized exam protocol. Obesity were defined by BMI-calculation (overweight: 25-29.9, obesity grade I: 30-34.9; obesity grade II: 35-39.9; obesity grade III: > 40) and by the absolute weight value. Body weight adapted contrast volume (targeted volume of 1.2 mL/kg for the 1st study and 0.8 mL/kg for the 2nd study) was applied in both groups. Dual Energy mode was used for both the DS-PCD-CT and the DS-EID-CT. Polychromatic images and VMI (40 keV and 70 keV) were reconstructed for both the DS-EID-CT and the DS-PCD-CT data (termed T3D). Two radiologists assessed subjective image quality using a 5-point Likert-scale. Each reader drew ROIs within parenchymatous organs and vascular structures to analyze image noise, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). RESULTS: Median time interval between scans was 12 months (Min: 6 months; Max: 36 months). BMI classification included overweight (n = 10, 14.7 %), obesity grade I (n = 38, 55.9 %), grade II (n = 13, 19.1 %) and grade III (n = 7, 10.3 %). The SNR achieved with DS-PCD-CT at QIR level 3was 12.61 vs. 11.47 (QIR 2) vs. 10.53 (DS-EID-CT), irrespective of parenchymatous organs. For vessels, the SNR were 16.73 vs. 14.20 (QIR 2) vs. 12.07 (DS-EID-CT). Moreover, the obtained median noise at QIR level 3 was as low as that of the DS-EID-CT (8.65 vs. 8.65). Both radiologists rated the image quality higher for DS-PCD-CT data sets (p < 0.05). The highest CNR was achieved at 40 keV for both scanners. T3D demonstrated significantly higher SNR and lower noise level compared to 40 keV and 70 keV. Median CTDIvol and DLP values for DS-PCD-CT and DS-EID-CT were 10.90 mGy (IQR: 9.31 - 12.50 mGy) vs. 16.55 mGy (IQR: 15.45 - 18.17 mGy) and 589.50 mGy * cm (IQR: 498.50 - 708.25 mGy * cm) vs. 848.75 mGy * cm (IQR: 753.43 - 969.58 mGy * cm) (p < 0.001). CONCLUSION: Image quality can be maintained while significantly reducing the contrast volume and the radiation dose (27% and 34% lower DLP and 31% lower CDTIvol) for abdominal contrast-enhanced CT using a 1st-generation DS-PCD-CT. Moreover, polychromatic reconstruction T3D on a DS-PCD-CT enables sufficient diagnostic image quality for oncological imaging.


Assuntos
Obesidade , Sobrepeso , Humanos , Idoso , Sobrepeso/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Abdome , Tomografia Computadorizada por Raios X , Tecnologia
17.
Diagnostics (Basel) ; 12(10)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36292231

RESUMO

The purpose of this study was to evaluate the potential of dual-energy CT (DECT) with virtual unenhanced imaging (VNC) and iodine maps (IM) to differentiate between intraperitoneal hematomas (IH) and bowel structures (BS) compared to linearly blended DECT (DE-LB) images (equivalent to single-energy CT). This retrospective study included the DECT of 30 patients (mean age: 64.5 ± 15.1 years, 19 men) with intraperitoneal hematomas and 30 negative controls. VNC, IM, and DE-LB were calculated. Imaging follow-up and surgical reports were used as references. Three readers assessed diagnostic performance and confidence in distinguishing IH and BS for DE-LB, VNC, and IM. Diagnostic confidence was assessed on a five-point Likert scale. The mean values of VNC, IM, and DE-LB were compared with nonparametric tests. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC). The results are reported as medians with interquartile ranges. Subjective image analysis showed higher diagnostic performance (sensitivity: 96.7−100% vs. 88.2−96.7%; specificity: 100% vs. 96.7−100%; p < 0.0001; ICC: 0.96−0.99) and confidence (Likert: 5; IRQ [5−5] vs. 4, IRQ [3−4; 4−5]; p < 0.0001; ICC: 0.80−0.96) for DECT compared to DE-LB. On objective image analysis, IM values for DECT showed significant differences between IH (3.9 HU; IQR [1.6, 8.0]) and BS (39.5 HU; IQR [29.2, 43.3]; p ≤ 0.0001). VNC analysis revealed a significantly higher attenuation of hematomas (50.5 HU; IQR [44.4, 59.4]) than BS (26.6 HU; IQR [22.8, 32.4]; p ≤ 0.0001). DE-LB revealed no significant differences between hematomas (60.5 HU, IQR [52.7, 63.9]) and BS (63.9 HU, IQR [58.0, 68.8]; p > 0.05). ROC analysis revealed the highest AUC values and sensitivity for IM (AUC = 100%; threshold by Youden-Index ≤ 19 HU) and VNC (0.93; ≥34.1 HU) compared to DE-LB (0.64; ≤63.8; p < 0.001). DECT is suitable for accurate discrimination between IH and BS by calculating iodine maps and VNC images.

18.
J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294324

RESUMO

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

19.
Quant Imaging Med Surg ; 12(9): 4622-4632, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36060581

RESUMO

Background: Modern CT might deliver higher image quality than necessary for fracture imaging, which would mean non-essential effective radiation exposure for patients. We simulated ultra-low dose (ULD)-CT at different dose levels and analyzed their diagnostic performance for scaphoid fracture detection. Methods: 30 consecutive high quality CT with clinically suspected scaphoid fractures were assessed. ULD-simulations were made at 20%, 10% and 5% of original dose. Three readers at different levels of experience (expert, moderate, inexperienced) expressed their diagnostic confidence (DC; 5-point-Likert-scale) and analyzed the presence and classification of scaphoid fractures within Krimmer's and Herbert's classifications. Effective radiation exposure of the original data sets and ULD-CT were calculated. Results: At 20% and 10% dose the more experienced readers reached perfect sensitivity (100%) and specificity (100%), showing perfect agreement regarding fracture classification (1.00). Diagnostic performance decreased at 5% dose (92.86% sensitivity, 100% specificity; expert reader). The inexperienced reader showed reduced sensitivity and specificity at all dose levels. At 10% dose minimal DC of all readers was 3/5 and mean calculated effective radiation exposure was 1.11 [±0.36] µSv. Conclusions: The results suggest that ULD-CT at 10% dose compared to high quality CT might offer sufficient image quality to precisely detect and classify scaphoid fractures, if moderate experience of the radiologist is granted.

20.
J Clin Med ; 11(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36079039

RESUMO

(1) Background: Compared to acute myocarditis in the initial phase, detection of subacute myocarditis with cardiac magnetic resonance (CMR) parameters can be challenging due to a lower degree of myocardial inflammation compared to the acute phase. (2) Objectives: To systematically evaluate non-invasive CMR imaging parameters in acute and subacute myocarditis. (3) Methods: 48 patients (age 37 (IQR 28−55) years; 52% female) with clinically suspected myocarditis were consecutively included. Patients with onset of symptoms ≤2 weeks prior to 1.5T CMR were assigned to the acute group (n = 25, 52%), patients with symptom duration >2 to 6 weeks were assigned to the subacute group (n = 23, 48%). CMR protocol comprised morphology, function, 3D-strain, late gadolinium enhancement (LGE) imaging and mapping (T1, ECV, T2). (4) Results: Highest diagnostic performance in the detection of subacute myocarditis was achieved by ECV evaluation either as single parameter or in combination with T1 mapping (applying a segmental or global increase of native T1 > 1015 ms and ECV > 28%), sensitivity 96% and accuracy 91%. Compared to subacute myocarditis, acute myocarditis demonstrated higher prevalence and extent of LGE (AUC 0.76) and increased T2 (AUC 0.66). (5) Conclusions: A comprehensive CMR approach allows reliable diagnosis of clinically suspected subacute myocarditis. Thereby, ECV alone or in combination with native T1 mapping indicated the best performance for diagnosing subacute myocarditis. Acute vs. subacute myocarditis is difficult to discriminate by CMR alone, due to chronological connection and overlap of pathologic findings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...